Structural Glazing
Sound insulating partition systems from INTEK
Product description
Special processes. For filigree beauty.
Structural glazing defines a specific type of glass facade construction in which glass panes are exclusively retained by bonding. In this special process we are bonding the glass panes directly to the glass frame. Structural glazing always requires an approval of the manufacturer of the adhesives (Dow Corning, Wacker-Chemie). Bonding is only allowed for licensed companies to which we belong since many years.
After completion of every “Structural-Glazing” order the submission of a production protocol with proofs of executed self-monitoring of the processor is required. The test report on the compliance with Guideline for European Technical Approval for bonded glass constructions ETAG no.002 must be submitted.
The width of the base frame with the bonding surface which is visible behind the glass panes may have a maximum of 20 millimeters. The thickness of the adhesive layer must be at least 4 millimeters in order to ensure that the adhesive layer is able to absorb different expansions of frame and glass at any time. The visible bonding must be available in the colours black and pale grey.
Fire protection: SG F 90 according to DIN 4102-13
A test report on a sound insulation of Rwp dB has to be submitted for this glazing.
High-end minimalism
Continuous glass surfaces without interfering frame profiles
Technical data
Material: Glass, wood, steel
Frame thickness: frameless
Sound protection: 47-51 dB
Fire protection: F30-F90
Structural glazing defines a specific type of glass facade construction in which glass panes are exclusively retained by bonding. In this special process we are bonding the glass panes directly to the glass frame. Structural glazing always requires an approval of the manufacturer of the adhesives (Dow Corning, Wacker-Chemie). Bonding is only allowed for licensed companies to which we belong since many years.
After completion of every “Structural-Glazing” order the submission of a production protocol with proofs of executed self-monitoring of the processor is required. The test report on the compliance with Guideline for European Technical Approval for bonded glass constructions ETAG no.002 must be submitted.
The width of the base frame with the bonding surface which is visible behind the glass panes may have a maximum of 20 millimeters. The thickness of the adhesive layer must be at least 4 millimeters in order to ensure that the adhesive layer is able to absorb different expansions of frame and glass at any time. The visible bonding must be available in the colours black and pale grey.
Fire protection: SG F 90 according to DIN 4102-13
A test report on a sound insulation of Rwp dB has to be submitted for this glazing.
High-end minimalism
Continuous glass surfaces without interfering frame profiles
Technical data
Material: Glass, wood, steel
Frame thickness: frameless
Sound protection: 47-51 dB
Fire protection: F30-F90
More about this product
Categorised in Sound insulation - Sound insulating partition systems - Office - Interior construction - Glass.
Manufacturer
INTEK
Family
Glass wall
Architonic ID
1391952
Similar products
Related Projects
This product has been archived. Product information may no longer be up to date.